MIL-M-80269
controlling the acceleration and deceleration of the slides. The resolution
of slide movement in either direction shall not be more than 0.0001 inch or
0.001 mm.
Absolute/incremental input.
The control shall have absolute/
3.4.10.6
incremental input capability. This mode shall be selected by a preparatory
G-code which may be switched during the tape program.
(Not required if BCL
input is specified (see 6.2.1).
Automatic tape code recognition.
The control shall have the
3.4. 10.7
capability to automatically recognize and read tape punched with either EIA
RS-244 or RS-358 (ASCII) character codes.
(Not required if BCL data input
is specified (see 6.2.1).
3.4.10.8 Switchable inch/metric input.
The control system shall provide
switchable inch/metric input capability.
3.4.10.9 Part program storage.
Unless otherwise specified (see 6.2.1),
part program storage shall be in either solid-state or bubble-type memory.
The MCU shall be capable of storing in memory the content of not less than
250 feet of postprocessed part program tape data unless otherwise specified
(see 6.2.1),
(Not applicable if BCL data input is specified (see 6.2.1).)
3.4.10.10 Standby battery power. Unless otherwise specified (see 6.2.1),
standby battery power shall be provided for controls having volatile memory,
to hold the memory provided at full load for a period of not less than 72
hours when the primary power source fails.
3.4.10.11 Part program edit. A program edit capability shall be provided
to allow block insertion, deletion or modification of any part program in
the part program memory. Data related to part program edit shall be input
by the manual data input provided on the control panel. Edited program data
entered into program memory shall be automatically acted upon, in the
sequence designated, whenever the part program is cycled.
3.4.10.12
Feed rate override.
A feed rate override control shall be
provided to allow manual adjustment of the programmed feed rate from zero to
not less than 120 percent of the programmed rate in either continuous
adjustment or in steps of not more than 10 percent.
The feed rate override
control shall have a position that allows return of feed rate to that
programmed.
3.4.10.13
Spindle speed override.
A spindle speed override shall be
provided to allow manual adjustment of spindle speed in either continuous
adjustment or in steps of not greater than 10 percent each.
The spindle
speed override control shall control not less than the range of override
percentages between 60 percent and 120 percent of programmed speed.
The
spindle speed override control shall have a position that allows return of
speed to that programmed.